MITA Control System Inverter for Cooling Technologies

MITA Control System

Inverter for Resourse Optimization

MITA Control System allows programming and modulating cooler’s performances during its operations in a very simple way. Electricity use optimization is granted.

Resourse use reduction.

Resourse use reduction. Enables water and electricity savings.

Noise reduction.

Noise reduction. Thanks to fan speed control according to ambient conditions.

Advanced consulting.

Advanced consulting. The value of a personal advisor, working alongside the customer for plant management needs.

How it Works

MITA offers an integrated control system with inverter as optional equipment for its units: MCS MITA Control System.

The minimum temperature limit theoretically achievable by a cooling tower is represented by the wet bulb temperature of the atmospheric air measured in the installation area. The correct sizing of a cooling tower is carried out considering the highest wet bulb value found during the year, without considering the variability of this temperature.

MITA Control System (MCS) constantly monitors the heat output, ensuring project performance as the wet bulb temperature varies and optimizing the cooling tower operations. Thus unnecessary waste during the day and year is avoided. MCS is a simple, reliable and efficient system which can be installed on board the machine or remotely. It is equipped with an inverter inserted in a panel with IP54 protection and it has a probe for temperature measurement.

Ask for a Quote

    Category:
    Application Field:


    MITA Connect & Cooling Station & PMS Tower for Fonderia Casati_Case Study

    Fonderia Casati is Industry 4.0 also thanks to MITA cooling systems

    Cooling technologies to support not only a process but a future vision of the business. Fonderia Casati, a long-standing company based in Varese, has no doubts on what it will take to keep its competitiveness at European level: the automation of its industrial processes, by implementing an integrated data flow between its production line and management control. MITA Cooling Technologies, therefore, provided this customer with an evaporative tower and a cooling management and monitoring station: the data collected by the system will, in fact, be sent to the company’s internal management and will help optimize the production processes.

    Learn More

    Tools to help you choose

    Cooling Advisors

    First goal: ask the right questions to the customer and involve him selecting the best cooler. We have been doing this since 1960.

    Preliminary plant evaluation

    The visit to the plant is a fundamental moment to find the right information on your needs, together with your technicians and the engineering firms involved.

    Tailor-made design

    Complete range of coolers and chillers, dozens of variants for each type, solutions for each application and important customizations: MITA's design is truly tailor-made.