Examples of processes: continuous cooling of servers, temperature control of sensitive environments, maintaining thermal safety of systems.
Datacenter Cooling
Cooling efficiency and reliability are critical in datacenters to ensure proper server operation and data security. MITA Cooling Technologies offers tailored solutions for dissipating the heat generated in highly energy-intensive data centers with different but always highly efficient cooling systems: evaporative towers, dry coolers and adiabatic coolers, chillers, and remote control technologies for optimized 24/7 monitoring and management.
Typical requirements: energy efficiency, H24 reliability, optimal peak heat management, low water use.
Cooling technologies offered: PME-E cooling towers, PAD-XL W adiabatic dry coolers, Frigofluid chillers, and advanced control systems.
1. Typical needs of the industry
In the datacenter sector, cooling is essential to keep systems and infrastructure running continuously and without risk of overheating. At stake is the smooth operation of highly energy-intensive but “sensitive” equipment.
Here are some of the key requirements.
- Energy efficiency: reduce energy consumption and optimize operating costs , limiting environmental impact.
- H24 reliability: cooling must be able to support uninterrupted operations to avoid server downtime and ensure data security.
- Intelligent control: automated temperature monitoring and management to adapt to heat peaks; it is also important to ensure cooling under varying loads.
- Minimization of water use: this is to contain supply costs and increase environmental sustainability.
2. Examples of datacenter processes served by cooling technology
Here are some practical examples of cooling processes applicable to the datacenter industry.
- Continuous cooling of high-performance servers: the dual objective is to maintain performance and ensure data security.
- Climate control of server rooms: constant temperature management in sensitive areas, protecting IT devices.
- Peak heat management during high data processing demand.
3. MITA Cooling Technologies' solutions for datacenters
MITA Cooling Technologies responds to these needs with solutions designed to ensure business continuity, efficiency and sustainability in data centers.
- PME-E open-circuit cooling towers: they ensure very high performance heat dissipation. An inverter system can optimize their energy efficiency, with low operating costs.
- PAD-XL W adiabatic dry coolers: ideal for environments where water use needs to be contained. These systems offer energy-efficient cooling with alternating dry operation and “adiabatic” pre-cooling (with little water).
- MDC-F and MDC-V dry coolers: modular and flexible air systems, ensuring reliable cooling without the need for water.
- Frigofluid Chillers with Free Cooling and Chillers with ecological refrigerants: reliable and high-performance “mechanical” coolers. Their special features, namely (respectively) optimized energy use and low GWP reduce environmental impact, not equipment efficiency.
- Inverter panels MITA Control System: a panel that enables automatic adjustment of operating speeds of devices. The purpose is to improve energy efficiency and extend equipment life.
- MITA IOT Remote Management Platform: an advanced system for monitoring from a 4.0 perspective, enabling performance monitoring and timely alerts.
Cooling systems for datacenters
PAD-XL W Adiabatic Cooler
Ideal for water saving maintaining a high efficiency. All operations are managed by PLC with the possibility of remote management in “Industry 4.0” mode. Suitable for both industrial and HVAC fields of application.
MDC-V V-Type Dry Cooler
Ease of installation, operation and maintenance–serving even large systems: this is the MDC-V V-shaped dry cooler. The peculiar design of the coils allows a larger heat exchange surface area than table-top dry cooler systems. All in an easily scalable solution.
PME-E Open-Circuit Evaporative Cooling Tower
A light and non-corrodible open-circuit evaporative cooling tower: process industry and HVAC operators will be able to count on its multiple versions and ease of transport and installation.
Cooling Towers in a Spanish Data Processing Center
TORRAVAL Cooling, part of the MITA Group, supplied 16 forced-draft cooling towers to one of Spain's largest data processing centers, helping to maintain optimal equipment performance. The chosen evaporative cooling system offers significant benefits in terms of energy efficiency and environmental impact, including noise reduction and utilization of the limited space available on the building's roof.
Learn MoreTools to help you choose
Cooling Advisors
Preliminary plant evaluation
Tailor-made design
Resources
Best practices
Read all Pieces of Advice by MITA Cooling TechnologiesWhat to Know
Find Out All Technical TermsTechnical Articles
Read All our Technical ArticlesNewsletter
Subscribe to MITA newsletter and stay updated on technical solutions for industrial and civil cooling and get to know our offer.